INDUSTRIAL RECTIFIER

endüstriyel redresörler (Edi Rectifier)

Industrial Rectifier

Industrial Rectifiers have special working algorithm. Since it has three phase input, it has good quality DC output signal. There is a distribution board suitable for the system.  The following configurations provide the perfect solution for industrial plants and power plants. Customized designs can be made ..

In the input isolation transformer, high gaussian sheets and H class copper wires are used and varnished under vacuum.

It has a wide range of information and control capabilities. It is the perfect alternative for the equivalent products obtained from abroad due to its quality, economic and service facilities.

Information about the operating status is given to the user with 0-10V and 4-20 mA analog signal and has the option of modbus communication.

Information of the operation status of the industrial rectifier can also be monitored on the TFT panel or LCD screen.

According to the usage area, cooling is done with panel type air conditioner. Our industrial rectifier is completely dry type and does not contain rectifier oil.

GENERAL FEATURES

  • Input Isolation Transformer
  • L-C Filter
  • Microprocessor controlled
  • Thyristor-thyristor Module Structure
  • Soft start opening
  • 2X16 Row LCD
  • EMI filter
  • Cooling with air conditioning
  • Interior lighting
  • Serial connection via panel
  • Emergency stop button
  • Dry contact information
  • Replacement AC wall socket
  • Fiberglass protection
  • Panel: branded or unmarked panel options
  • Ability to use as current source and voltage source
  • 24V / 48V / 110V / 220V / 500VDC options available
  • Production in the range of 10A – 1,000ADC.
  • 6-pulse or 12-pulse options
  • Choice of automatic or manual charging modes
  • Output voltage regulation with dropper diode
  • Battery monitoring, low battery information and protection in case of mains failure
  • Modbus communication
  • Monitoring and control via RS232-RS485,
  • Plinth height option suitable for needs
PROTECTION
  • Over Current (electronic)
  • Short circuit (electronic)
  • Semiconductor Extreme Heat
  • Transformer extreme heat
  • DC high (electronic)
  • DC Low (electronic)
  • Mains high (electronic)
  • Entry insurance
  • DC Output fuses
  • DC Distribution fuses
  • Emergency protection button
INDICATORS
  • 2×16 Row LCD display
  • Input voltage, output voltage, output current, error information tracking
  • Show language selection (English, Turkish)
  • Output voltage Analogue or Digital voltmeter
  • Output current Analogue or Digital ammeter
  • Led status notification
REMOTE ACCESS
  • ON-OFF Control
  • Rectifier Start
  • Output voltage adjustment with 0-10V control
  • 0-10V control Output Current Adjustment
WARNING AND OPERATING STATUS INFORMATION
  • DC High (Dry contact)
  • DC Low (Dry contact)
  • Mains High (dry contact)
  • Extreme Heat (dry contact)
  • Over Current (dry contact)
  • Earth leakage (dry contact)
  • Output voltage information with analog signal (0 – 10V or 4-20 mA)
  • Current signal with analog signal (0 – 10V or 4-20 mA)
CONNECTORS
  • input terminals
  • DC output terminals
  • Remote control terminal blocks
  • Warning information

Operating status analog information

  • Energy companies
  • Treatment plants
  • Electrodeionization applications

Tags: Industrial rectifiers, Industrial rectifiers, edirectifier, Industrial rectifiers, Coating rectifiers, industrial rectifiers – rectifier oil